Part No.: MPADFW-BACnet-to-IEC-61850
This series of products allows to integrate some IEC61850 devices into a BACnet network.
This series of products allows to integrate some IEC61850 devices into a BACnet network.
The HD67737-A1 is an IEC 61850 Server / BACnet Master Converter so you can connect an IEC 61850 Client network (for example a SCADA, HMI etc..) with some BACnet slaves in order to exchange informations between the nets.
The HD67738-A1 is an IEC 61850 Server / BACnet Slave Converter so you can connect an IEC 61850 Client network (for example a SCADA, HMI etc..) with a BACnet Master in order to exchange informations between the BACnet Master (for example a Supervisory System, PLC, etc..) and the IEC61850 network.
The HD67767-A1 is an IEC 61850 Client / BACnet Slave Converter so you can connect an IEC 61850 Server network (for example a Meters, Switces etc..) with a BACnet Master in order to exchange informations between the BACnet Master (for example a Supervisory System, PLC, etc..) and the IEC61850 network.
HD6773X-IP-A1 supports the connection on the BACnet side over Ethernet.
HD6773X-MSTP-A1 supports the connection on the BACnet side over RS485.
IEC 61850 Server / BACnet IP Master - Converter ( Housing type: A, Terminal Blocks Connectors )
Ports | 2xEthernet | |
---|---|---|
BACnet Protocol | BACnet IP Master | |
IEC 61850 Protocol | Server | |
Data Rates BACnet | 10/100 Base-T Autosensing | |
Data Rates IEC 61850 | 10/100 Base-T Autosensing | |
BACnet Connector | 3way 5mm terminal block | |
IEC 61850 Connector | RJ45 | |
Power Supply | 8..24V AC; 12..35V DC | |
Power Supply Connector | 2way 5mm terminal block | |
Operating Temperature | -40° to +85° (-40°F to +185°F) | |
Dimensions | 120x23x107 (DxWxH) | |
Weight | 200g approx | |
Mechanical Fixing | 35mm DIN Rail montage | |
Software | SW67737 |
IEC 61850 Server / BACnet MSTP Master - Converter ( Housing type: A, Terminal Blocks Connectors )
Ports | 2xEthernet | |
---|---|---|
BACnet Protocol | BACnet MSTP Master | |
IEC 61850 Protocol | Server | |
Data Rates BACnet | Up to 115200 bps | |
Data Rates IEC 61850 | 10/100 Base-T Autosensing | |
BACnet Connector | 3way 5mm terminal block | |
IEC 61850 Connector | RJ45 | |
Power Supply | 8..24V AC; 12..35V DC | |
Power Supply Connector | 2way 5mm terminal block | |
Operating Temperature | -40° to +85° (-40°F to +185°F) | |
Dimensions | 120x23x107 (DxWxH) | |
Weight | 200g approx | |
Mechanical Fixing | 35mm DIN Rail montage | |
Software | SW67737 |
IEC 61850 Server / BACnet IP Slave - Converter ( Housing type: A, Terminal Blocks Connectors )
Ports | 2xEthernet | |
---|---|---|
BACnet Protocol | BACnet IP Slave | |
IEC 61850 Protocol | Client | |
Data Rates BACnet | 10/100 Base-T Autosensing | |
Data Rates IEC 61850 | 10/100 Base-T Autosensing | |
BACnet Connector | RJ45 | |
IEC 61850 Connector | RJ45 | |
Power Supply | 8..24V AC; 12..35V DC | |
Power Supply Connector | 2way 5mm terminal block | |
Operating Temperature | -40° to +85° (-40°F to +185°F) | |
Dimensions | 120x23x107 (DxWxH) | |
Weight | 200g approx | |
Mechanical Fixing | 35mm DIN Rail montage | |
Software | SW67738 |
IEC 61850 Server / BACnet MSTP slave - Converter ( Housing type: A, Terminal Blocks Connectors )
Ports | 2xEthernet | |
---|---|---|
BACnet Protocol | BACnet MSTP Slave | |
IEC 61850 Protocol | Client | |
Data Rates BACnet | Up to 115200 bps | |
Data Rates IEC 61850 | 10/100 Base-T Autosensing | |
BACnet Connector | 3way 5mm terminal block | |
IEC 61850 Connector | RJ45 | |
Power Supply | 8..24V AC; 12..35V DC | |
Power Supply Connector | 2way 5mm terminal block | |
Operating Temperature | -40° to +85° (-40°F to +185°F) | |
Dimensions | 120x23x107 (DxWxH) | |
Weight | 200g approx | |
Mechanical Fixing | 35mm DIN Rail montage | |
Software | SW67738 |
IEC 61850 Client / BACnet IP Slave - Converter ( Housing type: A, Terminal Blocks Connectors )
Ports | 2xEthernet | |
---|---|---|
BACnet Protocol | BACnet IP Slave | |
IEC 61850 Protocol | Client | |
Data Rates BACnet | 10/100 Base-T Autosensing | |
Data Rates IEC 61850 | 10/100 Base-T Autosensing | |
BACnet Connector | RJ45 | |
IEC 61850 Connector | RJ45 | |
Power Supply | 8..24V AC; 12..35V DC | |
Power Supply Connector | 2way 5mm terminal block | |
Operating Temperature | -40° to +85° (-40°F to +185°F) | |
Dimensions | 120x23x107 (DxWxH) | |
Weight | 200g approx | |
Mechanical Fixing | 35mm DIN Rail montage | |
Software | SW67767 |
IEC 61850 Client / BACnet MSTP slave - Converter ( Housing type: A, Terminal Blocks Connectors )
Ports | 2xEthernet | |
---|---|---|
BACnet Protocol | BACnet MSTP Slave | |
IEC 61850 Protocol | Client | |
Data Rates BACnet | Up to 115200 bps | |
Data Rates IEC 61850 | 10/100 Base-T Autosensing | |
BACnet Connector | 3way 5mm terminal block | |
IEC 61850 Connector | RJ45 | |
Power Supply | 8..24V AC; 12..35V DC | |
Power Supply Connector | 2way 5mm terminal block | |
Operating Temperature | -40° to +85° (-40°F to +185°F) | |
Dimensions | 120x23x107 (DxWxH) | |
Weight | 200g approx | |
Mechanical Fixing | 35mm DIN Rail montage | |
Software | SW67767 |
Order Code | Description |
---|---|
AC34011 | Isolated Converter 100..240V AC to 12V DC stabilized - AC/DC |
AC34012 | Isolated Converter 100..240V AC to 24V DC stabilized - AC/DC |
AC34131 | Patch Cross Cable Cat6 2 Meters |