CANopen: Repeater/ Isolator CANopen

Part No.: MPADFW-CANopen-Repeater-Isolator-CANopen
The ranges includes various products for solving all the needs to change the communication baudrate.

產品介紹

CANopen REPEATER/ISOLATOR

The ranges includes various products for solving all the needs of a CAN line like extension of the line, increase of nodes number, isolation of CANopen branches, protection from spikes noise and electrostatic charger or simply to change the communication baudrate.

The HD67117 and HD67117M devices are repeaters/isolators for CANopen buses.

The HD67117R, HD67117-A3 and HD67117-A4 devices are repeaters/isolators with a 3kV isolation between the two CANopen bus.

The HD67117F and the HD67117FSX are generic CANopen repeaters that allows to extend a CANopen network through Multi-Modal optic fiber.

The converters are available also in another version, ideal for STRONG applications.

The corresponding models are:

  • HD67402 – CANopen Repeater, STRONG

These converters are contained in a metal housing, so it is STRONG and RESISTANT to the vibrations and shocks. The electrical parts are with triple isolation of 4000 V between CANopen/CANopen - CANopen/Power Supply - CANopen/Power Supply.
Particularly suitable for the installation on cars, trains, boats, industrial sector and in fragile environments.
Two versions, one with Varnished PCB and one with Resined PCB.
Varnished treatment gives dust and humidity protection, Resined treatment gives high water, dust and vibrations protection.
Excellent range of temperature resistance from -40°C to +105°C, features required by AUTOMOTIVE applications.

 

Series CANOpen Repeater

 

HD67117

CANopen - Repeater - Extender bus line ( Housing type: A, Terminal Blocks Connectors )



 

Ports 2xCAN
CAN2.0 Connector Terminal block
DATA Rates Up to 1Mbps
Power Supply 10...19V AC ; 10...35V DC
Operating Temperature -40ºC/+85ºC (-40ºF/+185ºF)
Dimensions 120x23x107 mm(DxWxH)
Weight 200g approx
Mechanical Fixing DIN Rail montage

HD67117M

CANopen - Repeater - Extender bus line ( Housing type: Small Size, Terminal Blocks Connetors )



 

Ports 2xCAN
CAN2.0 Connector Terminal block
DATA Rates Up to 1Mbps
Power Supply 10...19V AC ; 10...35V DC
Operating Temperature -40ºC/+85ºC (-40ºF/+185ºF)
Dimensions 60x71x95  mm(DxWxH)
Weight 200g approx
Mechanical Fixing DIN Rail montage

HD67117R

CANopen - Repeater - Extender bus line ( Housing type: R, Terminal Blocks Connectors, Galvanic Isolation: 3KV )



 

Ports 2xCAN
CAN2.0 Connector Terminal block
DATA Rates Up to 1Mbps
Power Supply 10...19V AC ; 10...35V DC
Operating Temperature -40ºC/+85ºC (-40ºF/+185ºF)
Dimensions 86x23x96 mm(DxWxH)
Weight 200g approx
Mechanical Fixing DIN Rail montage

HD67117-A3

CANopen - Repeater - Extender bus line ( Housing type: A, M12 Connectors, Galvanic Isolation: 3KV )



 

Ports 2xCAN
CAN2.0 Connector M12 connector
DATA Rates Up to 1Mbps
Power Supply 8...19V AC ; 8...35V DC
Operating Temperature -40ºC/+85ºC (-40ºF/+185ºF)
Dimensions 120x36x107 mm(DxWxH)
Weight 200g approx
Mechanical Fixing DIN Rail montage

HD67117-A4

CANopen - Repeater - Extender bus line ( Housing type: A, Mini-Fit Connectors, Galvanic Isolation: 3KV )



 

Ports 2xCAN
CAN2.0 Connector  
DATA Rates Up to 1Mbps
Power Supply 8...19V AC ; 8...35V DC
Operating Temperature -40ºC/+85ºC (-40ºF/+185ºF)
Dimensions 120x23x107 mm(DxWxH)
Weight 200g approx
Mechanical Fixing DIN Rail montage

 

CANopen - Repeater - Extender bus line

Products supplied with metal housing (Housing type: E), are STRONG and RESISTANT to mechanical stress (such as vibration and shock), electrical parts with a triple isolation 4 kV between CAN0/CAN1 - CAN0/Power Supply - CAN1/Power Supply.

Particularly suitable for installation in cars, trucks, trains, boats, in the industrial sector and in fragile environments. .

Two versions, one with a coating of the PCB (suffix code V) that ensures IP65 and another encapsulation with resin (suffix code R) which gives to device the high performance safety and insulation for wet environments (IP67) and to resist to noise. .

This product can be mounted on any type of surface (horizontal, vertical and oblique) with four fixing lugs, also you can choose the type of connector, Mini-Fit or Superseal 1.5. .

Excellent range of temperature resistance from -40 ° C to +105 ° C, features required by AUTOMOTIVE.

 

HD67402-E4V

CANopen - Repeater - Extender bus line ( Housing type: E, Mini-Fit Connectors, Triple Galvanic Isolation: 4KV, PCB Treatment: Varnished )



 

Ports 2xCAN
Data Rates CAN Up to 1000k bps
CAN Connector 3way Mini-Fit®
Power Supply Connector 2way Mini-Fit®
Power Supply 10..40V DC; 8..26V AC
Operating Temperature -40°C/+105°C (-40°F/+221°F)
Dimensions Without Fixing Lugs 76x86x40 (LxWxH)
Dimensions With Fixing Lugs A 105x86x40 (LxWxH)
Dimensions With Fixing Lugs B 83x112.5x40 (LxWxH)
Dimensions With Fixing Lugs C 105x112.5x40 (LxWxH)
Weight 200g approx
Mechanical Fixing DIN Rail montage

HD67402-E4R

CANopen - Repeater - Extender bus line ( Housing type: E, Mini-Fit Connectors, Triple Galvanic Isolation: 4KV, PCB Treatment: Resined )



 

Ports 2xCAN
Data Rates CAN Up to 1000k bps
CAN Connector 3way Mini-Fit®
Power Supply Connector 2way Mini-Fit®
Power Supply 10..40V DC; 8..26V AC
Operating Temperature -40°C/+105°C (-40°F/+221°F)
Dimensions Without Fixing Lugs 76x86x40 (LxWxH)
Dimensions With Fixing Lugs A 105x86x40 (LxWxH)
Dimensions With Fixing Lugs B 83x112.5x40 (LxWxH)
Dimensions With Fixing Lugs C 105x112.5x40 (LxWxH)
Weight 200g approx
Mechanical Fixing DIN Rail montage

HD67402-E7V

CANopen - Repeater - Extender bus line ( Housing type: E, SuperSeal 1.5 Connectors, Triple Galvanic Isolation: 4KV, PCB Treatment: Varnished )



 

Ports 2xCAN
Data Rates CAN Up to 1000k bps
CAN Connector 3way AMP SuperSeal 1.5
Power Supply Connector 2way AMP SuperSeal 1.5
Power Supply 10..40V DC; 8..26V AC
Operating Temperature -40°C/+105°C (-40°F/+221°F)
Dimensions Without Fixing Lugs 76x86x40 (LxWxH)
Dimensions With Fixing Lugs A 105x86x40 (LxWxH)
Dimensions With Fixing Lugs B 83x112.5x40 (LxWxH)
Dimensions With Fixing Lugs C 105x112.5x40 (LxWxH)
Weight 200g approx
Mechanical Fixing DIN Rail montage

HD67402-E7R

CANopen - Repeater - Extender bus line ( Housing type: E, SuperSeal 1.5 Connectors, Triple Galvanic Isolation: 4KV, PCB Treatment: resined )



 

Ports 2xCAN
Data Rates CAN Up to 1000k bps
CAN Connector 3way SuperSeal 1.5
Power Supply Connector 2way SuperSeal 1.5
Power Supply 10..40V DC; 8..26V AC
Operating Temperature -40°C/+105°C (-40°F/+221°F)
Dimensions Without Fixing Lugs 76x86x40 (LxWxH)
Dimensions With Fixing Lugs A 105x86x40 (LxWxH)
Dimensions With Fixing Lugs B 83x112.5x40 (LxWxH)
Dimensions With Fixing Lugs C 105x112.5x40 (LxWxH)
Weight 200g approx
Mechanical Fixing DIN Rail montage

 

Series CANopen Repeater Optic fibres

 

HD67117F

CANopen / Optic Fiber - Repeater - Extender bus line


 

Ports 1xCAN; 2x Optic Fibres
CAN2.0 Connector Terminal block
Optic Fibres Connector ST 820 um
DATA Rates CAN2.0 Up to 1Mbps
DATA Rates Optic Fibres Up to 1Mbps
Power Supply 10...19V AC ; 10...35V DC
Operating Temperature -40ºC/+85ºC (-40ºF/+185ºF)
Dimensions 120x23x107 mm(DxWxH)
Weight 200g approx
Mechanical Fixing DIN Rail montage

HD67117FSX

CANopen / Optic Fiber - Repeater - Extender bus line ( High Performance )


 

Ports 1xCAN; 2x Optic Fibres
CAN2.0 Connector Terminal block
Optic Fibres Connector ST 820 um
DATA Rates CAN2.0 Up to 1Mbps
DATA Rates Optic Fibres 1Mbps
Power Supply 10...19V AC ; 10...35V DC
Operating Temperature -40ºC/+85ºC (-40ºF/+185ºF)
Dimensions 120x23x107 mm(DxWxH)
Weight 200g approx
Mechanical Fixing DIN Rail montage


As a repeater, strictly said, that transfer the signal from one device to another without any processing of the signal itself: the use of a repeater is appropriate when the lines are electrical noise or transfer distances are high and you must use a extensor line, for very large distances, it is advisable to use the Fibres optic devices that have coverage up to 2 km.



As isolator, the device can be inserted in two lines of the same protocol for passing data, but in a way that they still remain galvanically isolated.



As bridge: if the signal to be transferred needs to be changed in speed (baudrate) in this case, the repeater device can also be used as a bridge.



Otherwise if you want to manipulate the signal further (CobId, filter, etc..) Is useful to use our device to CANopen or CAN Bridge:



See Bridge CANopen CANopen data filtrate

See Bridge CAN  CAN data filtrate

See Bridge CAN  CAN data filtrate Optic Fibres

 

Example of application

   

   

 

Accessories


Order Code  Description
AC34011 Isolated Converter 100..240V AC to 12V DC stabilized - AC/DC
AC34012 Isolated Converter 100..240V AC to 24V DC stabilized - AC/DC
AC34107 Null Modem Cable, Fem/Fem, DSub 9 Pin, 1.8 m
AC34114 Null Modem Cable, Fem/Fem, DSub 9 Pin, 5 m